This research includes the adding of TiO2 nanotube to metallic cement (glue) and investigates how it effect on some mechanical characteristics. These characteristics involved wear, tensile strength, compression and hardness. XRD and SEM/EDS did the description of prepared cement alloys with five wt% of TiO2 (0.5, 1.5, 2.5, 3.5 and 5 wt%). The experimental results demonstrated that the diametral-tensile-strength, compression, wear and hardness have been increased with increasing wt.% of added TiO2.
Volume 12 | 05-Special Issue
Pages: 682-690
DOI: 10.5373/JARDCS/V12SP5/20201804